Open calculator ↗

Heat pump versus boiler lifecycle cost · Calculation guide

Meet the same annual useful heat demand. Use seasonal COP and boiler efficiency.

Calculation guide

Discount constant year-end energy and maintenance costs over a common life.

adv = boilerCost-pumpCost+(heat*fuel/(eff/100)+boilerMaint-heat*electric/cop-pumpMaint)/pmt(1,rate*12,years)

Inputs

Annual useful heat (kWh)

Example entry 20000.0.

Seasonal heat pump COP

Example entry 4.0. Minimum 1e-12.

Boiler efficiency (%)

Example entry 80.0 %. Allowed range 1e-12 to 100.

Electricity price per kWh

Example entry 0.3 (in the selected currency).

Fuel price per kWh

Example entry 0.1 (in the selected currency).

Installed heat pump cost

Example entry 15000.0 (in the selected currency).

Installed boiler cost

Example entry 8000.0 (in the selected currency).

Annual heat pump maintenance

Example entry 150.0 (in the selected currency).

Annual boiler maintenance

Example entry 250.0 (in the selected currency).

Comparison years

Example entry 10.0. Minimum 1. Use whole numbers.

Annual discount rate (%)

Example entry 0.0 %. Allowed range 0 to 100.

Worked example

InputValue
Annual useful heat (kWh)20,000
Seasonal heat pump COP4
Boiler efficiency (%)80%
Electricity price per kWh0.3
Fuel price per kWh0.1
Installed heat pump cost15,000
Installed boiler cost8,000
Annual heat pump maintenance150
Annual boiler maintenance250
Comparison years10
Annual discount rate (%)0%
ResultValue
Present-value saving with heat pump4,000

Calculation steps

Present-value saving with heat pump = ((Installed boiler cost − Installed heat pump cost) + ((((((Annual useful heat (kWh) × Fuel price per kWh) ÷ (Boiler efficiency (%) ÷ 100)) + Annual boiler maintenance) − ((Annual useful heat (kWh) × Electricity price per kWh) ÷ Seasonal heat pump COP)) − Annual heat pump maintenance) ÷ payment(1, (Annual discount rate (%) × 12), Comparison years)))

((8,000 − 15,000) + ((((((20,000 × 0.1) ÷ (80 ÷ 100)) + 250) − ((20,000 × 0.3) ÷ 4)) − 150) ÷ payment(1, (0 × 12), 10))) = 4,000

Interpreting the result

Positive present-value saving favors the heat pump over the common comparison life.

How each input affects this example

Each row starts from the worked example and changes one input.

InputOriginal inputNew inputAffected resultOriginal resultNew result
Annual useful heat (kWh)20,00022,000Present-value saving with heat pump4,0005,000
Seasonal heat pump COP45Present-value saving with heat pump4,0007,000
Boiler efficiency (%)80%88%Present-value saving with heat pump4,0001,727.272727
Electricity price per kWh0.31.3Present-value saving with heat pump4,000-46,000
Fuel price per kWh0.11.1Present-value saving with heat pump4,000254,000
Installed heat pump cost15,00016,500Present-value saving with heat pump4,0002,500
Installed boiler cost8,0008,800Present-value saving with heat pump4,0004,800
Annual heat pump maintenance150165Present-value saving with heat pump4,0003,850
Annual boiler maintenance250275Present-value saving with heat pump4,0004,250
Comparison years1011Present-value saving with heat pump4,0005,100
Annual discount rate (%)0%1%Present-value saving with heat pump4,0003,418.434984